I then tried the pump at various speeds and it did not prime and circulate the water through the pool. The arrow at the top of the hex nut points in the direction of the water flow. EC65 uses 6 lbs, and EC75 uses 9 lbs, but since DE is half as light as others a lb of DE powder is more than 2 cups of dry measure, its actually closer to 4 cups. In most cases, no worries that it will blow-out to leave a leaking pump running. Any ideas as to what could be the problem? If the new pump produces greater flow rate than the old pump, it produces high pressure, and poor filtration, and can damage the cartridge. Contact a professional for further assistance. I turned it on and it ran fine for about one hour. dual-speed pool pump. If none of those things, perhaps the filter grid needs to be soaked in a Filter Cleaner, to remove oils or minerals that have clogged the pores of the fabric. Size: PCB Main Circuit Board PCB Display Board PCB Main Circuit Board PCB Main Circuit Board PCB Display Board Also, make sure you plug in the cell all the way. Now I am looking to replace the old filter. Not normal, but cant see a reason why that would cause the seal to fail. Then after it cools Im able to spin the shaft and it starts again. Hi Joe, the Perflex DE filter has a few dozen flex tubes covered in a mesh fabric. Thanks. The spider gasket as it is called, inside of the valve is not sealing the waste port like it should. There should be at least 12 of straight pipe before the switch. Hmmm, now if the breaker were stopping the power from flowing to the switch, the timeclock would lose time, and would not turn itself on. You could also use a Hayward 24 sand filter, item E3324. . I think I have some air leakage on my supply side of my Hayward Super Pump. If the motor shaft wont turn, you can work it loose by spinning the shaft with pliers on the front end of the shaft, or a 7/16 wrench on the back end of the shaft. Dont let pool pump problems drive you crazy! Otherwise if not, you go in thru the back of the motor, remove the capacitor bracket to drop the cap out of the way, so you can slip a 7/16 wrench on the slotted back 1/2 of the shaft, and work it back and forth for 30 seconds to break the rust. Thank you I have taken the thing apart several times and cleaned those fingers but that wasnt the problem this timeI took a chance and tried the vacuum to see if any debris actually made it to the filter basket and nothing went throughso got a plunger and forced the water through with that and then the pump finally primed!! If still stumped, use a power meter to find the problem lies where the power dies, and trace power from the breaker to the timer or outlet, to the motor. Do they sometimes have to be replaced? Thanks again! The outlet the pump is plugged into, I suppose that is a 240V outlet. Running at low rpm seems to be fine. I get home from work and the pump is running. What is the problem. Not sure if Hayward will cover, but if you have your original purchase invoice, check the warranty for your pump, should be able to find on haywardnet.com to see if bearings are excluded, or to check the warranty period. Tested the switch on and off and it works as expected. Pumps can also leak water from the shaft seal, which can appear to be a housing/seal plate leak, but will leak only directly from the bottom. Replace with the exact same MFD number capacitor if defective (they can be tested) the capacitor is the battery that starts the motor. Hi Mark, in looking at the owners manual https://www.intheswim.com/images/PDFs/E1964-Manual.pdf perhaps there is a minimum speed setting that is set to high, or the programming Day/Time/Speed is set up to permit high speed only? Likewise, check if the motor is wired correctly for the available field supply voltage. They do not seem to have enough stooch even though they are rated at 1HP like my original motor. If it does make a hum or buzz sound, it could be a bad capacitor, the black cylinder at 9 oclock, in the rear of the motor. Its a good piece of troubleshooting. Disconnected the chlorination device, and direct connected it eliminating that. Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. We have a circuit board that controls these two motors as well as an LED light. Checked pump later, not running with message Drive error, heatsync overheated. Most likely, and unfortunately yes. When the pressure rises 7-9 psi above the clean, start-up pressure, that indicates that its time to backwash or clean the filter. I replaced my old hayward maxflow pump with the new variable speed sp2670020vsp. The Hayward swim profilter is making a loud noise and the top vibtrates. It wont stop leaking. I backflushed the filter and pump would loose almost all water in basket. Did I mention low water level, stuck skimmer weirs, or clogged skimmer baskets? What should I check? easier. Does that have to be over the two spades or one? second most common is the pump lid or drain plug, lube the lid oring and teflon tape on the drain plug. All pipes are 1.5 and solidly installed with primer and high quality glue for the PVC used. Other problems that could cause this could include a (very) clogged impeller, something actually preventing the shaft from turning or it could be a bad capacitor, a black cylinder in the rear of the motor. the termistor was blown. please help. ), and the pipe that threads into the pump (is it loose, shrunken? Remove the bracket and inspect for bulging, cracking, or burnt marks on the end. Next, maintain the proper salt levelin the pool. Would this make the breaker flip? I did notice the on/off switch was mushy moving from the on and off positions. Thanks for your time! If it reoccurs, you may have some pipe problems, such as a collapsed flexible PVC pipe on the skimmer. Hi, make sure that the switches are not loose, the centrifugal switch on the end of the shaft and the Stationary switch at 6 oclock. Thanks. Could be from a large buildup of rust inside, between the stator and motor, but that usually frees up after running for just a minute. Water at the base of the pump: 1. could be from a loose pump lid, dripping when the pump is off, 2. could be a leaking outlet pipe fitting, oozing from where water leaves the pump, and running down the sides of the volute, and dripping off the bottom, or 3. could be the shaft seal failing, behind the impeller. Hi Donna, the screws that are removed to rotate are the long thru-bolts that run thru the motor, and are turned at the rear of the motor (spray with WD-40 first). If that doesnt solve the problem, then work through the steps below. Now the backwash is leaking a small amount water and the pump seems to be surging instead of running smoothly. Replace the plumbing with a new fitting, using a silicone thread sealant and 3-4 wraps of teflon tape clockwise. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. Any idea how to correct this. Settings while on Auto: 4200, 88, 26.8, 3.85, 91p, -4200, AI-0, R1.59, T3. I replaced the rod, and now my lid will not go down, the rod is the exact same as the other. then I tried to switch it on again but the pump wont start. This quick spray of water when you shut the pump off, as you have experienced, are a useful tool in locating an air leak on a pump. I checked valves inside pump, and new o ring was installed. "caption": "In The Swim Blog"
My salt water pool was shut down for the winter. First time pool owner (obviously dont know what we are doing). I just got my home back, I walked outside and pool level was well below jets. Remove all of the bolts around the top and pull out the Filter Nest, or all of the fingers. It is being practiced by thousands of pool owners just like you. Click here to shop our store. Hi Mark, should it be 115V? Upon resetting an electrical short sound came from the pump motor tripping the breaker a second time. K-1766 Taylor Salt Test Thats unusual, shouldve fixed it. I removed the capacitor and had it tested at a local pool store and they told me it was fine. If I wait for a few minutes after that, the pump starts up again at full speed. Do you have any suggestions? We opened the pool a few weeks back with no pump motor problems. Now Im getting small air bubbles when the speed is on low. If you have a visible motor shaft, just behind the impeller, common on older pumps or booster pumps, you can just grab it with straight pliers and turn it back and forth. {
If the water is running down between the pump and motor, determine if its dripping out of the plumbing fitting on top or the shaft seal on the bottom. men's rhinestone dress shoes. Then, I tried plugged the pump into another power outlet and it still does not work. I have water coming out the side of the sand filter where u would back wash? High water flow (>125 gpm) into the heater. Hi Curt, not especially uncommon, small stress cracks on the outlet port of the pump, about 1/4 long? Thanks. I owe you a beer if you are ever around my neck of the woods. If I prime the pump and turn it on it runs fine but when I turn it off and let it set for a few minutes you can hear it cheering then the water in the pump evacuates and there appears to be some water coming from the bottom of the pump. The only thing I can think of now is a bad breaker box which is outside adjacent to the pump, it is 20 years old. Troubleshooting pool heaters is a methodical process, or a process of elimination. Issues with Hayward Blue Essence | Trouble Free Pool Or buy a new motor. A visual tip-off is something that is dripping water when the pump is OFF, or that sprays water for half-a-second at the instant the pump shuts off, is drawing air in, when the pump is runnning. },
If still nothing, look for damage in the rear of the motor, something burned, melted, loose, or pinched or cut wires. If you suspect your breaker has broken, call a certified electrician to further diagnose the problem. If your sweeper has a booster pump, could be a problem with a clogged impeller, or air leak into the pump, or some other pump issue. So in actuality the pump is only being used 4 months a year for 8 hours a day. Also be sure the vent holes for the motor are not blocked. Flow switches require a minimum flow fate of 11 gallons per minute to stay consistently closed, Water temperature is below 50 degrees F. (The cell output scales back to 20% once it reaches 60 degrees F and shuts off at 50 degrees F.). with UV, Ozone and Hydroxyl Radicals. Before you purchase a new Hayward pool pump, its important to verify that the pump is the right size for your pool piping. Not sure if this is somehow related to the water being heated or maybe air in the pump just guesses. After doing some reading, I now understand that the IG pump shouldnt be used with the AG pool and weve been doing the wrong thing for almost 30 years. The salt cylinder is clean. I recently noticed what appears to be a shaft seal leak. Be sure though, that the motor has plenty of air flow, and the air flow vents are not blocked, and that incoming voltage is not too high or too low. If you need a new one in a few days, I would not consider getting one from Hayward, that could take a month. Reset the average salt level on startup and whenever you replace your cell. Hi Robin, an F5 code? At that moment the generation led turns on and turns off after a few seconds. anyway I digress. Some pumps are stronger than some hose, so check to see if the hose is not collapsing under the suction, during the issue. "datePublished": "3/27/2015",
Inside there is an o-ring that may be out of position, or need lubricant.
Ford Transit Fuel Pressure Sensor Location,
Nina Hart Gary Cause Of Death,
Southwest Conference Track And Field Records,
Are Camellias Poisonous To Cattle,
Jb Mauney Married Samantha Lyne,
Articles H